Buy Mil Spares is your sourcing solution for top-quality military and defense parts, aerospace parts, and other similar products that are necessary for operational fulfillment. You have reached the RFQ page for part number UPL2-27930-2, a Circuit Breaker item that is listed with the NSN 5925-01-425-1842 for an ease of identification. Manufactured by Vdo Control Systems Inc and readily available for procurement today, you are always welcome to request a quote on this NSN part to receive tailored pricing information and fulfillment options from our team. Simply offer us important information like your desired quantity, price, and fulfillment timeframe, and our team will supply you with a tailored quote on part number UPL2-27930-2 in 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that customers quickly identify and procure exact items, we list everything with as much relevant information as possible. For example, while part number UPL2-27930-2 is manufactured by Vdo Control Systems Inc, it is specifically done so under CAGE Code 82227, a unique identifier assigned to a specific facility by the DLA that supplies to various government or defense agencies. Furthermore, using the first digits of the NSN 5925-01-425-1842, one can also determine that this part falls under FSC 5925 Circuit Breakers. With this in mind, continue exploring our website today, and see how we can help you secure competitive pricing and rapid lead times on all desired NSN parts.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-425-1842 Item PartTypeName: CIRCUIT BREAKER | 5925 | 014251842 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
UPL2-27930-2 | 5 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
CQXF | Inclosure Protection Type For Which Designed | GENERAL PURPOSE |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
AKPX | Pole Quantity | 2 |
CPRX | Actuator Position Designation | AT EACH POLE |
CPSM | Internal Trip Release Configuration | SERIES TRIP W/DUAL RATING ALL LOCATIONS |
FEAT | Special Features | HANDLE COLOR IS BLACK. |
CPLM | Maximum Continuous Load Current Rating Per Pole | 50.0 AMPERES DC ALL LOCATIONS |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 65.0 DC ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 5000.0 DC ALL LOCATIONS |
MRC | Decoded Requirement | Clear Text Reply |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.100 MINIMUM AT 200 PCT ALL LOCATIONS AND 1.700 MAXIMUM AT 200 PCT ALL LOCATIONS |
TTQY | Terminal Type And Quantity | 4 THREADED STUD |
CPRW | Actuator Function | TRIP-RESET |