Buy Mil Spares is your sourcing solution for top-quality military and defense parts, aerospace parts, and other similar products that are necessary for operational fulfillment. You have reached the RFQ page for part number GF 5080 50C BR, a Filter Radio Frequency Interfere item that is listed with the NSN 5915-01-042-2424 for an ease of identification. Manufactured by Spectrum Control Inc and readily available for procurement today, you are always welcome to request a quote on this NSN part to receive tailored pricing information and fulfillment options from our team. Simply offer us important information like your desired quantity, price, and fulfillment timeframe, and our team will supply you with a tailored quote on part number GF 5080 50C BR in 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that customers quickly identify and procure exact items, we list everything with as much relevant information as possible. For example, while part number GF 5080 50C BR is manufactured by Spectrum Control Inc, it is specifically done so under CAGE Code 13050, a unique identifier assigned to a specific facility by the DLA that supplies to various government or defense agencies. Furthermore, using the first digits of the NSN 5915-01-042-2424, one can also determine that this part falls under FSC 5915 Filters and Networks. With this in mind, continue exploring our website today, and see how we can help you secure competitive pricing and rapid lead times on all desired NSN parts.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5915-01-042-2424 Item PartTypeName: FILTER,RADIO FREQUENCY INTERFERE | 5915 | 010422424 | Y | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | ||||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
GF-5080-50C-BR | 5 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 9.900 INCHES NOMINAL |
ADAQ | BODY LENGTH | 6.900 INCHES NOMINAL |
ADAT | BODY WIDTH | 4.700 INCHES NOMINAL |
ADAU | BODY HEIGHT | 3.500 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.205 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 7.430 INCHES NOMINAL |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 3.500 INCHES NOMINAL |
AFGA | OPERATING TEMP RANGE | -55.0 TO 85.0 DEG CELSIUS |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 3RD RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 4TH RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 50.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 50.0 2ND RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 50.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 50.0 4TH RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.25 VOLTS AC 1ST RADIO INTERFERENCE AND 4.0 VOLTS DC 1ST RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.25 VOLTS AC 2ND RADIO INTERFERENCE AND 4.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.25 VOLTS AC 3RD RADIO INTERFERENCE AND 4.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.25 VOLTS AC 4TH RADIO INTERFERENCE AND 4.0 VOLTS DC 4TH RADIO INTERFERENCE |
AHCG | MAXIMUM TEMP RISE | 25.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 UNTHREADED HOLE |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 4 THREADED STUD INPUT 1ST FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 4 THREADED STUD OUTPUT 2ND FUNCTION |
CQDZ | MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE | 800.0 VOLTS AT SEA LEVEL |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 125.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION AND 400.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 125.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION AND 400.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 125.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION AND 400.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 125.0 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION AND 400.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
CQRG | BODY MATERIAL | METAL |
CRDC | MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 250.0 VOLTS AT SEA LEVEL |
CRST | BODY SURFACE TREATMENT | TIN |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |