Buy Mil Spares is your sourcing solution for top-quality military and defense parts, aerospace parts, and other similar products that are necessary for operational fulfillment. You have reached the RFQ page for part number DU 1 4, a Transformer Power item that is listed with the NSN 5950-00-518-7522 for an ease of identification. Manufactured by Signal Transformer Co Inc and readily available for procurement today, you are always welcome to request a quote on this NSN part to receive tailored pricing information and fulfillment options from our team. Simply offer us important information like your desired quantity, price, and fulfillment timeframe, and our team will supply you with a tailored quote on part number DU 1 4 in 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that customers quickly identify and procure exact items, we list everything with as much relevant information as possible. For example, while part number DU 1 4 is manufactured by Signal Transformer Co Inc, it is specifically done so under CAGE Code 08779, a unique identifier assigned to a specific facility by the DLA that supplies to various government or defense agencies. Furthermore, using the first digits of the NSN 5950-00-518-7522, one can also determine that this part falls under FSC 5950 Coils and Transformers. With this in mind, continue exploring our website today, and see how we can help you secure competitive pricing and rapid lead times on all desired NSN parts.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-518-7522 Item PartTypeName: TRANSFORMER,POWER | 5950 | 005187522 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
DU-1/4 | 6 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHED |
ABHP | OVERALL LENGTH | 5.312 INCHES MAXIMUM5.312 INCHES MAXIMUM5.312 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP4.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP4.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 5.250 INCHES MAXIMUM5.250 INCHES MAXIMUM5.250 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 4.250 INCHES MAXIMUM4.250 INCHES MAXIMUM4.250 INCHES MAXIMUM |
ABTD | MOUNTING SLOT WIDTH | 0.196 INCHES NOMINAL SINGLE GROUP0.196 INCHES NOMINAL SINGLE GROUP0.196 INCHES NOMINAL SINGLE GROUP |
ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 500.0 HERTZ MAXIMUM SINGLE COMPONENT500.0 HERTZ MAXIMUM SINGLE COMPONENT500.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 0.250 VOLT-AMPERE SINGLE COMPONENT0.250 VOLT-AMPERE SINGLE COMPONENT0.250 VOLT-AMPERE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | OPENOPENOPEN |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND FLANGE SINGLE GROUP AND FLANGE SINGLE GROUP AND SLOT SINGLE GROUPSLOT SINGLE GROUPSLOT SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 2 PRIMARY SINGLE COMPONENT AND 2 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT2 SECONDARY SINGLE COMPONENT2 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 2.2 AMPERES AC MAXIMUM SINGLE COMPONENT ALL SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 104.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY AND 104.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY AND 110.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY AND 110.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY AND 120.00 AC VO |
CWJS | WINDING OPERATING VOLTAGE | 104.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY OR 104.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY OR 110.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY OR 110.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY OR 120.00 A |
TTQY | TERMINAL TYPE AND QUANTITY | 16 THREADED STUD |