Buy Mil Spares is your sourcing solution for top-quality military and defense parts, aerospace parts, and other similar products that are necessary for operational fulfillment. You have reached the RFQ page for part number 209-3-1-41-3-8-20, a Circuitbreaker item that is listed with the NSN 5925-01-570-0584 for an ease of identification. Manufactured by Sensata Technologies Inc and readily available for procurement today, you are always welcome to request a quote on this NSN part to receive tailored pricing information and fulfillment options from our team. Simply offer us important information like your desired quantity, price, and fulfillment timeframe, and our team will supply you with a tailored quote on part number 209-3-1-41-3-8-20 in 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that customers quickly identify and procure exact items, we list everything with as much relevant information as possible. For example, while part number 209-3-1-41-3-8-20 is manufactured by Sensata Technologies Inc, it is specifically done so under CAGE Code 81541, a unique identifier assigned to a specific facility by the DLA that supplies to various government or defense agencies. Furthermore, using the first digits of the NSN 5925-01-570-0584, one can also determine that this part falls under FSC 5925 Circuit Breakers. With this in mind, continue exploring our website today, and see how we can help you secure competitive pricing and rapid lead times on all desired NSN parts.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-570-0584 Item PartTypeName: CIRCUIT BREAKER | 5925 | 015700584 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
209-3-1-41-3-8-20 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AKPX | Pole Quantity | 3 |
CPLM | Maximum Continuous Load Current Rating Per Pole | 20.0 AMPERES AC ALL LOCATIONS |
MRC | Decoded Requirement | Clear Text Reply |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 120.0 AC ALL LOCATIONS AND 240.0 AC ALL LOCATIONS |
FREQ | Frequency In Hertz | 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
AXHR | Mounting Facility Type And Quantity | 6 THREADED HOLE |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 1000.0 ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRX | Actuator Position Designation | AT EACH POLE |
CPRT | Manual Actuator Type And Quantity | 3 TOGGLE |
CPRW | Actuator Function | TRIP-RESET |
AJWX | Mounting Surface To Terminal End Distance | 3.550 INCHES NOMINAL |
THSD | Thread Series Designator | M |
TTQY | Terminal Type And Quantity | 6 SCREW |
AGAV | End Item Identification | ORDALT 16581, MK86 MOD1, CONTROL, ANTENNA |
AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 5000.0 AC ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.200 MINIMUM AT 200 PCT ALL LOCATIONS AND 2.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
CPRY | External Actuator Linkage Arrangement | ONE, TWO, AND THREE LINKED |
ADTV | Case Material | PLASTIC |
CQJX | Nominal Thread Size | 6.0 MILLIMETERS |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.