Buy Mil Spares is your sourcing solution for top-quality military and defense parts, aerospace parts, and other similar products that are necessary for operational fulfillment. You have reached the RFQ page for part number 7274-12-5, a Circuit Breaker item that is listed with the NSN 5925-00-982-9657 for an ease of identification. Manufactured by Sensata Technologies Inc and readily available for procurement today, you are always welcome to request a quote on this NSN part to receive tailored pricing information and fulfillment options from our team. Simply offer us important information like your desired quantity, price, and fulfillment timeframe, and our team will supply you with a tailored quote on part number 7274-12-5 in 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that customers quickly identify and procure exact items, we list everything with as much relevant information as possible. For example, while part number 7274-12-5 is manufactured by Sensata Technologies Inc, it is specifically done so under CAGE Code 82647, a unique identifier assigned to a specific facility by the DLA that supplies to various government or defense agencies. Furthermore, using the first digits of the NSN 5925-00-982-9657, one can also determine that this part falls under FSC 5925 Circuit Breakers. With this in mind, continue exploring our website today, and see how we can help you secure competitive pricing and rapid lead times on all desired NSN parts.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-00-982-9657 Item Description: CIRCUIT BREAKER | 5925 | 009829657 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
7274-12-5 | 2 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
CQXF | Inclosure Protection Type For Which Designed | SANDTIGHT AND |
AKPX | Pole Quantity | 1 |
AAQL | Body Style | SINGLE POLE TYPE |
CQXF | Inclosure Protection Type For Which Designed | SHOCKPROOF |
CPLM | Maximum Continuous Load Current Rating Per Pole | 5.0 AMPERES AC AND |
AFJN | Fragility Factor | MODERATELY RUGGED |
PKWT | Unpackaged Unit Weight | 1.500 OUNCES |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
ABXD | Bushing Length | 0.250 INCHES NOMINAL |
AEFQ | Nonturn Device Length | 0.078 INCHES NOMINAL |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 120.0 AC AND |
FREQ | Frequency In Hertz | 400.0 SINGLE LOCATION |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 28.0 DC SINGLE LOCATION |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 2000.0 DC SINGLE LOCATION |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 800.0 AC AND |
AXHR | Mounting Facility Type And Quantity | 1 THREADED BUSHING |
CPRJ | Trip Release Method | THERMAL SINGLE LOCATION |
AEFP | Nonturn Device Radius | 0.388 INCHES NOMINAL |
ADAT | Body Width | 0.562 INCHES MAXIMUM |
AEFR | Nonturn Device Width | 0.110 INCHES NOMINAL |
CPRL | Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
CPRQ | Reset Method | MANUAL |
CRCF | Trip Release Ambient Temp Rating | 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 145.0 SINGLE LOCATION |
CPRT | Manual Actuator Type And Quantity | 1 PUSH-PULL |
ADTV | Case Material | PLASTIC |
CPRW | Actuator Function | TRIP-RESET |
CPSM | Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
CPRX | Actuator Position Designation | AT POLE ONE |
CQJX | Nominal Thread Size | 0.438 INCHES |
ADAQ | Body Length | 0.750 INCHES MAXIMUM |
AEFN | Nonturn Device Location | AT 12 OCLOCK |
THSD | Thread Series Designator | UN |
AJWX | Mounting Surface To Terminal End Distance | 1.707 INCHES NOMINAL |
MRC | Decoded Requirement | Clear Text Reply |
APNQ | Arc Quenching Method | AIR |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.703 INCHES NOMINAL |
TTQY | Terminal Type And Quantity | 2 TAB W/SCREW |
CPLM | Maximum Continuous Load Current Rating Per Pole | 5.0 AMPERES DC SINGLE LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 20.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 2.000 MINIMUM AT 200 PCT AND |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CMLP | Thread Quantity Per Inch | 32 |
CQXF | Inclosure Protection Type For Which Designed | CORROSION RESISTANT AND |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.