Buy Mil Spares is your sourcing solution for top-quality military and defense parts, aerospace parts, and other similar products that are necessary for operational fulfillment. You have reached the RFQ page for part number 50127-1042, a Relay Electromagnetic item that is listed with the NSN 5945-00-539-2386 for an ease of identification. Manufactured by Safran Power Usa Llc and readily available for procurement today, you are always welcome to request a quote on this NSN part to receive tailored pricing information and fulfillment options from our team. Simply offer us important information like your desired quantity, price, and fulfillment timeframe, and our team will supply you with a tailored quote on part number 50127-1042 in 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that customers quickly identify and procure exact items, we list everything with as much relevant information as possible. For example, while part number 50127-1042 is manufactured by Safran Power Usa Llc, it is specifically done so under CAGE Code 3CPE0, a unique identifier assigned to a specific facility by the DLA that supplies to various government or defense agencies. Furthermore, using the first digits of the NSN 5945-00-539-2386, one can also determine that this part falls under FSC 5945 Relays and Solenoids. With this in mind, continue exploring our website today, and see how we can help you secure competitive pricing and rapid lead times on all desired NSN parts.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-00-539-2386 Item PartTypeName: RELAY,ELECTROMAGNETIC | 5945 | 005392386 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
A837B | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 1.82 AMPERES DC ALL WINDINGS |
CSKP | NONPILE-UP AUXILIARY CONTACT ARRANGEMENT | 2 POLE,SINGLE THROW,NORMALLY CLOSED,MOMENTARY ACTION |
CSQC | AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 DC |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS ALL WINDINGS |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 3.0 AMPERES DC RESISTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 DC |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
TTQY | TERMINAL TYPE AND QUANTITY | 14 PIN ALL FUNCTIONS |
AAJD | THREAD CLASS | 2B SINGLE MOUNTING FACILITY |
ABHP | OVERALL LENGTH | 4.620 INCHES NOMINAL |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.406 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 3.680 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 2.250 INCHES NOMINAL |
AKDX | WINDING QUANTITY | 3 |
APCN | COIL QUANTITY | 3 |
APNA | WINDING DC RESISTANCE RATING | 16.0 OHMS NOMINAL FIRST WINDING |
APNA | WINDING DC RESISTANCE RATING | 175.0 OHMS NOMINAL THIRD WINDING |
APNA | WINDING DC RESISTANCE RATING | 9.5 OHMS NOMINAL SECOND WINDING |
APNP | DUTY TYPE | CONTINUOUS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE SINGLE MOUNTING FACILITY |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE MOUNTING FACILITY |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE,SINGLE THROW,NORMALLY CLOSED,MOMENTARY ACTION |