Buy Mil Spares is your sourcing solution for top-quality military and defense parts, aerospace parts, and other similar products that are necessary for operational fulfillment. You have reached the RFQ page for part number 73C828-001, a Transformer Power item that is listed with the NSN 5950-00-945-0650 for an ease of identification. Manufactured by Robert M Hadley Company Inc and readily available for procurement today, you are always welcome to request a quote on this NSN part to receive tailored pricing information and fulfillment options from our team. Simply offer us important information like your desired quantity, price, and fulfillment timeframe, and our team will supply you with a tailored quote on part number 73C828-001 in 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that customers quickly identify and procure exact items, we list everything with as much relevant information as possible. For example, while part number 73C828-001 is manufactured by Robert M Hadley Company Inc, it is specifically done so under CAGE Code 72964, a unique identifier assigned to a specific facility by the DLA that supplies to various government or defense agencies. Furthermore, using the first digits of the NSN 5950-00-945-0650, one can also determine that this part falls under FSC 5950 Coils and Transformers. With this in mind, continue exploring our website today, and see how we can help you secure competitive pricing and rapid lead times on all desired NSN parts.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-945-0650 Item PartTypeName: TRANSFORMER,POWER | 5950 | 009450650 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
8201425-001 | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.115 INCHES MINIMUM SINGLE MOUNTING FACILITY 4TH CENTER GROUP AND 2.135 INCHES MAXIMUM SINGLE MOUNTING FACILITY 4TH CENTER GROUP |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.734 INCHES MINIMUM SINGLE MOUNTING FACILITY 2ND CENTER GROUP AND 2.766 INCHES MAXIMUM SINGLE MOUNTING FACILITY 2ND CENTER GROUP |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.734 INCHES MINIMUM SINGLE MOUNTING FACILITY 3RD CENTER GROUP AND 2.766 INCHES MAXIMUM SINGLE MOUNTING FACILITY 3RD CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.052 INCHES MINIMUM SINGLE MOUNTING FACILITY 4TH CENTER GROUP AND 1.072 INCHES MAXIMUM SINGLE MOUNTING FACILITY 4TH CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.234 INCHES MINIMUM SINGLE MOUNTING FACILITY 2ND CENTER GROUP AND 2.266 INCHES MAXIMUM SINGLE MOUNTING FACILITY 2ND CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.234 INCHES MINIMUM SINGLE MOUNTING FACILITY 3RD CENTER GROUP AND 2.266 INCHES MAXIMUM SINGLE MOUNTING FACILITY 3RD CENTER GROUP |
ABKW | OVERALL HEIGHT | 1.922 INCHES MINIMUM AND 1.954 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO SINGLE PHASE SINGLE COMPONENT AND THREE PHASE TO THREE PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-WYE |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.609 INCHES MINIMUM AND 3.641 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.734 INCHES MINIMUM AND 2.766 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 170.0 DEG CELSIUS |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 2.234 INCHES MINIMUM SINGLE MOUNTING FACILITY 1ST CENTER GROUP AND 2.266 INCHES MAXIMUM SINGLE MOUNTING FACILITY 1ST CENTER GROUP |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 2 1ST GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 4 2ND GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 4 3RD GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 4 4TH GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE ALL GROUPINGS |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES 2ND GROUP |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES 3RD GROUP |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES 1ST GROUP |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES 4TH GROUP |
CRBZ | WINDING OPERATING CURRENT | 4.0 AMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 743.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 26.0 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 29.13 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 198.90 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 39.20 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 6.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
TEST | TEST DATA DOCUMENT | 04660-73C828 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWI |
THSD | THREAD SERIES DESIGNATOR | UNC ALL GROUPINGS |
TTQY | TERMINAL TYPE AND QUANTITY | 13 TURRET |