Buy Mil Spares is your sourcing solution for top-quality military and defense parts, aerospace parts, and other similar products that are necessary for operational fulfillment. You have reached the RFQ page for part number PS-2-2457-5, a Circuit Breaker item that is listed with the NSN 5925-00-075-7892 for an ease of identification. Manufactured by Navair And Navsea Managed and readily available for procurement today, you are always welcome to request a quote on this NSN part to receive tailored pricing information and fulfillment options from our team. Simply offer us important information like your desired quantity, price, and fulfillment timeframe, and our team will supply you with a tailored quote on part number PS-2-2457-5 in 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that customers quickly identify and procure exact items, we list everything with as much relevant information as possible. For example, while part number PS-2-2457-5 is manufactured by Navair And Navsea Managed, it is specifically done so under CAGE Code 10001, a unique identifier assigned to a specific facility by the DLA that supplies to various government or defense agencies. Furthermore, using the first digits of the NSN 5925-00-075-7892, one can also determine that this part falls under FSC 5925 Circuit Breakers. With this in mind, continue exploring our website today, and see how we can help you secure competitive pricing and rapid lead times on all desired NSN parts.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-00-075-7892 Item Description: Circuit Breaker | 5925 | 000757892 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Ps-2-2457-5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
CQXF | Inclosure Protection Type For Which Designed | EXPLOSION PROOF AND FUNGUS RESISTANT AND MOISTURE RESISTANT |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.062 INCHES NOMINAL |
AAQL | Body Style | SINGLE POLE TYPE |
MRC | Decoded Requirement | Clear Text Reply |
CPLM | Maximum Continuous Load Current Rating Per Pole | 5.0 AMPERES AC SINGLE LOCATION |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC SINGLE LOCATION |
CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
CPRJ | Trip Release Method | MAGNETIC-HYDRAULIC SINGLE LOCATION |
FREQ | Frequency In Hertz | 60.0 SINGLE LOCATION |
AXHR | Mounting Facility Type And Quantity | 2 THREADED HOLE |
AKPX | Pole Quantity | 1 |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 SINGLE LOCATION |
ADAT | Body Width | 0.750 INCHES NOMINAL |
CPRL | Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
CPRQ | Reset Method | MANUAL |
AJEC | Boss Height | 0.125 INCHES NOMINAL |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRW | Actuator Function | TRIP-RESET |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
CPSM | Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
THSD | Thread Series Designator | UNF |
CQJX | Nominal Thread Size | 0.190 INCHES |
TTQY | Terminal Type And Quantity | 2 THREADED STUD |
AJWX | Mounting Surface To Terminal End Distance | 1.359 INCHES NOMINAL |
ADTV | Case Material | PLASTIC |
ADAQ | Body Length | 2.500 INCHES NOMINAL |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.938 INCHES NOMINAL |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC SINGLE LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 75.000 NOMINAL AT 100 PCT SINGLE LOCATION AND 10.000 MINIMUM AT 125 PCT SINGLE LOCATION AND 75.000 MAXIMUM AT 125 PCT SINGLE LOCATION AND 5.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 9.000 MAXIMUM AT 200 PCT SINGLE LOCATION AND 0.700 MINIMUM AT 400 PCT SINGLE LOCATION AND 2.000 MAXIMUM AT 400 PCT SINGLE LOCATION AND 0.500 MINIMUM AT 500 PCT SINGLE LOCATION AND 1.000 MAXIMUM AT 500 PCT SINGLE LOCATION |
CMLP | Thread Quantity Per Inch | 32 |
CPRP | Ultimate Trip Time Per Pole In Seconds | 10.000 MINIMUM SINGLE LOCATION AND 75.000 MAXIMUM SINGLE LOCATION |
CPRX | Actuator Position Designation | BETWEEN POLE ONE AND TWO |