Buy Mil Spares is your sourcing solution for top-quality military and defense parts, aerospace parts, and other similar products that are necessary for operational fulfillment. You have reached the RFQ page for part number 687007, a Transformer Power item that is listed with the NSN 5950-00-295-8596 for an ease of identification. Manufactured by Lockheed Martin Corporation and readily available for procurement today, you are always welcome to request a quote on this NSN part to receive tailored pricing information and fulfillment options from our team. Simply offer us important information like your desired quantity, price, and fulfillment timeframe, and our team will supply you with a tailored quote on part number 687007 in 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that customers quickly identify and procure exact items, we list everything with as much relevant information as possible. For example, while part number 687007 is manufactured by Lockheed Martin Corporation, it is specifically done so under CAGE Code 56232, a unique identifier assigned to a specific facility by the DLA that supplies to various government or defense agencies. Furthermore, using the first digits of the NSN 5950-00-295-8596, one can also determine that this part falls under FSC 5950 Coils and Transformers. With this in mind, continue exploring our website today, and see how we can help you secure competitive pricing and rapid lead times on all desired NSN parts.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-295-8596 Item PartTypeName: TRANSFORMER,POWER | 5950 | 002958596 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
687007 | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.234 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.234 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.234 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.266 INCHES MAXIMUM SINGLE MO |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.109 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.109 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.109 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.141 INCHES MAXIMUM SINGLE MO |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT400.0 HERTZ NOMINAL SINGLE COMPONENT400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 130.0 VOLT-AMPERE SINGLE COMPONENT130.0 VOLT-AMPERE SINGLE COMPONENT130.0 VOLT-AMPERE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 2.969 INCHES MAXIMUM2.969 INCHES MAXIMUM2.969 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.781 INCHES MAXIMUM2.781 INCHES MAXIMUM2.781 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 3.938 INCHES MAXIMUM3.938 INCHES MAXIMUM3.938 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 150.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSEDFULLY INCLOSEDFULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUPTHREADED HOLE SINGLE GROUPTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT1 SECONDARY SINGLE COMPONENT1 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP0.164 INCHES SINGLE GROUP0.164 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 2.0 MILLIAMPERES AC MINIMUM SINGLE COMPONENT SINGLE PRIMARY AND 4.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
CRBZ | WINDING OPERATING CURRENT | 600.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 17.60 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 17.60 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 35.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 35.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 47.6 |
CWJS | WINDING OPERATING VOLTAGE | 17.60 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 6.30 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY6.30 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY35.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 47.60 AC VOL |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 11 TAB,SOLDER LUG |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote