Buy Mil Spares is your sourcing solution for top-quality military and defense parts, aerospace parts, and other similar products that are necessary for operational fulfillment. You have reached the RFQ page for part number 1207847, a Relay Electromagnet item that is listed with the NSN 5945-01-369-0793 for an ease of identification. Manufactured by Lockheed Martin Corporation and readily available for procurement today, you are always welcome to request a quote on this NSN part to receive tailored pricing information and fulfillment options from our team. Simply offer us important information like your desired quantity, price, and fulfillment timeframe, and our team will supply you with a tailored quote on part number 1207847 in 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that customers quickly identify and procure exact items, we list everything with as much relevant information as possible. For example, while part number 1207847 is manufactured by Lockheed Martin Corporation, it is specifically done so under CAGE Code 56232, a unique identifier assigned to a specific facility by the DLA that supplies to various government or defense agencies. Furthermore, using the first digits of the NSN 5945-01-369-0793, one can also determine that this part falls under FSC 5945 Relays and Solenoids. With this in mind, continue exploring our website today, and see how we can help you secure competitive pricing and rapid lead times on all desired NSN parts.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-01-369-0793 Item PartTypeName: RELAY,ELECTROMAGNETIC | 5945 | 013690793 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
1207847 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
TTQY | TERMINAL TYPE AND QUANTITY | 10 THREADED STUD ALL FUNCTIONS |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.171 INCHES NOMINAL SINGLE MOUNTING FACILITY |
APCN | COIL QUANTITY | 1 |
APNQ | ARC QUENCHING METHOD | AIR |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
CRXH | TIME DELAY | 0.025 SECONDS MAXIMUM FIXED RELEASE TIME |
CRXH | TIME DELAY | 0.05 SECONDS MAXIMUM FIXED OPERATE TIME |
CSKP | NONPILE-UP AUXILIARY CONTACT ARRANGEMENT | 1 POLE,SINGLE THROW,NORMALLY OPEN,MOMENTARY ACTION |
CSQC | AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 55.0 AMPERES AC AND 15.0 AMPERES DC MOTOR LOAD |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 3.0 AMPERES AC AND 3.0 AMPERES DC RESISTIVE LOAD |
TEST | TEST DATA DOCUMENT | 53711-6022170 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAW |
ABHP | OVERALL LENGTH | 2.600 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 2.500 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 2.440 INCHES MAXIMUM |
AKDX | WINDING QUANTITY | 1 |
APNP | DUTY TYPE | CONTINUOUS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE,SINGLE THROW,NORMALLY OPEN,MOMENTARY ACTION |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 55.0 AMPERES AC AND 10.0 AMPERES DC LAMP LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 55.0 AMPERES AC AND 15.0 AMPERES DC INDUCTIVE LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 55.0 AMPERES AC AND 25.0 AMPERES DC RESISTIVE LOAD |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
APNA | WINDING DC RESISTANCE RATING | 200.0 OHMS NOMINAL SINGLE WINDING |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES AC AND 1.0 AMPERES DC LAMP LOAD |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 3.0 AMPERES AC AND 3.0 AMPERES DC INDUCTIVE LOAD |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote