Buy Mil Spares is your sourcing solution for top-quality military and defense parts, aerospace parts, and other similar products that are necessary for operational fulfillment. You have reached the RFQ page for part number ALPHA 3807-01GD, a Powersupply item that is listed with the NSN 6130-01-398-9105 for an ease of identification. Manufactured by International Power Sources Inc and readily available for procurement today, you are always welcome to request a quote on this NSN part to receive tailored pricing information and fulfillment options from our team. Simply offer us important information like your desired quantity, price, and fulfillment timeframe, and our team will supply you with a tailored quote on part number ALPHA 3807-01GD in 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that customers quickly identify and procure exact items, we list everything with as much relevant information as possible. For example, while part number ALPHA 3807-01GD is manufactured by International Power Sources Inc, it is specifically done so under CAGE Code 0JSW7, a unique identifier assigned to a specific facility by the DLA that supplies to various government or defense agencies. Furthermore, using the first digits of the NSN 6130-01-398-9105, one can also determine that this part falls under FSC 6130 Converters Electrical Non Rotating. With this in mind, continue exploring our website today, and see how we can help you secure competitive pricing and rapid lead times on all desired NSN parts.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-398-9105 Item PartTypeName: POWER SUPPLY | 6130 | 013989105 | 0 | N | B | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | B | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
ALPHA 3807-01GD | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ANPM | INPUT PHASE | SINGLE 2ND ALTERNATE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 220.0 AC POUNDS PER HOUR DRY 3RD ALTERNATE OPERATING POWER RQMT AND 230.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 3RD ALTERNATE OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 48.0 HERTZ MINIMUM 2ND ALTERNATE OPERATING POWER RQMT AND 62.0 HERTZ MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
CWHC | OUTPUT CONTROL LOCATION | REAR PANEL SINGLE POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | CONNECTOR,RECEPTACLE SINGLE POWER OUTPUT |
CWHM | INPUT CURRENT RATING | 70.0 AC AMPERES NOMINAL 3RD ALTERNATE OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 1 2ND ALTERNATE OPERATING POWER RQMT |
ABKW | OVERALL HEIGHT | 5.250 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 13.110 INCHES NOMINAL |
ANPM | INPUT PHASE | SINGLE 1ST ALTERNATE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 120.0 AC POUNDS PER HOUR DRY 2ND ALTERNATE OPERATING POWER RQMT AND 130.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 2ND ALTERNATE OPERATING POWER RQMT |
CWKG | VENTILATION DESIGN TYPE | CONVECTION |
ABHP | OVERALL LENGTH | 19.000 INCHES NOMINAL |
AGAV | END ITEM IDENTIFICATION | F-15 |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ANPM | INPUT PHASE | SINGLE 3RD ALTERNATE OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE 4TH ALTERNATE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 230.0 AC POUNDS PER HOUR DRY 4TH ALTERNATE OPERATING POWER RQMT AND 250.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 4TH ALTERNATE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | 0.0 DC KILOVOLTS MINIMUM SINGLE POWER OUTPUT AND 30.0 DC KILOVOLTS MAXIMUM SINGLE POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 48.0 HERTZ MINIMUM 1ST ALTERNATE OPERATING POWER RQMT AND 62.0 HERTZ MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 48.0 HERTZ MINIMUM 3RD ALTERNATE OPERATING POWER RQMT AND 62.0 HERTZ MAXIMUM 3RD ALTERNATE OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 48.0 HERTZ MINIMUM 4TH ALTERNATE OPERATING POWER RQMT AND 62.0 HERTZ MAXIMUM 4TH ALTERNATE OPERATING POWER RQMT |
CWGH | OUTPUT CURRENT RATING | 0.0 DC MILLIAMPERES MINIMUM SINGLE POWER OUTPUT AND 1.5 DC MILLIAMPERES MAXIMUM SINGLE POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 1 SINGLE POWER OUTPUT |
CWHM | INPUT CURRENT RATING | 70.0 AC AMPERES NOMINAL 1ST ALTERNATE OPERATING POWER RQMT |
CWHM | INPUT CURRENT RATING | 70.0 AC AMPERES NOMINAL 2ND ALTERNATE OPERATING POWER RQMT |
CWHM | INPUT CURRENT RATING | 70.0 AC AMPERES NOMINAL 4TH ALTERNATE OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 1 1ST ALTERNATE OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 1 3RD ALTERNATE OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 1 4TH ALTERNATE OPERATING POWER RQMT |
FEAT | SPECIAL FEATURES | OUTPUT VOLTAGE ANALOG METER,CONTROL SELECTOR SWITCH,VOLTAGE AND CURRENT ADJUSTABLE,LOCAL CONTROL POTENTIOMETER,ELECTROSTATIC SENSITIVE DEVICE |
APNX | INPUT VOLTAGE RATING | 90.0 AC POUNDS PER HOUR DRY 1ST ALTERNATE OPERATING POWER RQMT AND 110.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 1ST ALTERNATE OPERATING POWER RQMT |
AYNH | OPERATING AMBIENT TEMP RANGE | 0.1/50.0 DEG CELSIUS |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote