Buy Mil Spares is your sourcing solution for top-quality military and defense parts, aerospace parts, and other similar products that are necessary for operational fulfillment. You have reached the RFQ page for part number 80G144, a Transformer Power item that is listed with the NSN 5950-00-552-0960 for an ease of identification. Manufactured by General Electric Company and readily available for procurement today, you are always welcome to request a quote on this NSN part to receive tailored pricing information and fulfillment options from our team. Simply offer us important information like your desired quantity, price, and fulfillment timeframe, and our team will supply you with a tailored quote on part number 80G144 in 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that customers quickly identify and procure exact items, we list everything with as much relevant information as possible. For example, while part number 80G144 is manufactured by General Electric Company, it is specifically done so under CAGE Code 03512, a unique identifier assigned to a specific facility by the DLA that supplies to various government or defense agencies. Furthermore, using the first digits of the NSN 5950-00-552-0960, one can also determine that this part falls under FSC 5950 Coils and Transformers. With this in mind, continue exploring our website today, and see how we can help you secure competitive pricing and rapid lead times on all desired NSN parts.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-552-0960 Item PartTypeName: TRANSFORMER,POWER | 5950 | 005520960 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
80G846-3 | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHED |
ABHP | OVERALL LENGTH | 3.312 INCHES MAXIMUM3.312 INCHES MAXIMUM3.312 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.359 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.359 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.359 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.391 INCHES MAXIMUM SINGLE MO |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.359 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.359 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.359 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.391 INCHES MAXIMUM SINGLE MO |
ABKW | OVERALL HEIGHT | 4.406 INCHES MAXIMUM4.406 INCHES MAXIMUM4.406 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 2.562 INCHES MAXIMUM2.562 INCHES MAXIMUM2.562 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT60.0 HERTZ NOMINAL SINGLE COMPONENT60.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 12.0 DECIBELS SINGLE COMPONENT12.0 DECIBELS SINGLE COMPONENT12.0 DECIBELS SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | FULLY INCLOSEDFULLY INCLOSEDFULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUPTHREADED STUD SINGLE GROUPTHREADED STUD SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT2 SECONDARY SINGLE COMPONENT2 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.190 INCHES SINGLE GROUP0.190 INCHES SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 77.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 110.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 220.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 310.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 92.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 12 TAB,SOLDER LUG |