Buy Mil Spares is your sourcing solution for top-quality military and defense parts, aerospace parts, and other similar products that are necessary for operational fulfillment. You have reached the RFQ page for part number BRL011, a Relay Electromagnetic item that is listed with the NSN 5945-01-470-1862 for an ease of identification. Manufactured by General Dynamics Satcom and readily available for procurement today, you are always welcome to request a quote on this NSN part to receive tailored pricing information and fulfillment options from our team. Simply offer us important information like your desired quantity, price, and fulfillment timeframe, and our team will supply you with a tailored quote on part number BRL011 in 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that customers quickly identify and procure exact items, we list everything with as much relevant information as possible. For example, while part number BRL011 is manufactured by General Dynamics Satcom, it is specifically done so under CAGE Code 1GD22, a unique identifier assigned to a specific facility by the DLA that supplies to various government or defense agencies. Furthermore, using the first digits of the NSN 5945-01-470-1862, one can also determine that this part falls under FSC 5945 Relays and Solenoids. With this in mind, continue exploring our website today, and see how we can help you secure competitive pricing and rapid lead times on all desired NSN parts.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-01-470-1862 Item PartTypeName: RELAY,ELECTROMAGNETIC | 5945 | 014701862 | N | A | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
A | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
BRL011 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | Overall Length | 50.0 MILLIMETERS NOMINAL |
AXHR | Mounting Facility Type And Quantity | 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
ABMK | Overall Width | 40.0 MILLIMETERS NOMINAL |
ABKW | Overall Height | 81.6 MILLIMETERS NOMINAL |
MRC | Decoded Requirement | Clear Text Reply |
CSXF | Operating Voltage Rating And Type At Specified Temp | 120.0 VOLTS AC 25 DEG CELSIUS ALL WINDINGS |
TTQY | Terminal Type And Quantity | 8 STANDARD TUBE BASE ALL FUNCTIONS |
CWAB | Main Contact Maximum Voltage Rating In Volts | 250.0 AC |
AJSS | Frequency In Hertz | 50.0 MINIMUM AND 60.0 MAXIMUM |
CTDL | Main Contact Load Current Rating At Maximum Rated Voltage | 3.0 AMPERES AC RESISTIVE LOAD |
FEAT | Special Features | THIS SOLID-STATE TIMER RELAY CAN BE SET TO TIME RANGES OF 0.1 TO 1.0 SECONDS, 1.0 TO 10.0 SECONDS, 0.1 TO 1.0 MINUTES, AND 1.0 TO 10.0 MINUTES BY CHANGING ONE OF FOUR WHITE MULTIPLIER KEYS; TIME LIMIT CONTACT IS DPDT; OPERATING VOLTAGE IS 85 TO 110 PERCENT OF 120 VAC; POWER CONSUMPTION IS 2 VA NOMINAL; INSULATION RESISTANCE IS 100 MEGOHMS; WITHSTANDS DIELECTRIC STRENGTH OF 2000 VAC; VIBRATION AND SHOCK RESISTANT; AMBIENT OPERATING TEMPERATURE IS MINUS 10 TO PLUS 50 DEG. C; AMBIENT STORAGE TEMPERATURE IS MINUS 25 TO PLUS 80 DEG. C; RELATIVE HUMIDITY 45 TO 85 PERCENT; HAS POWER ON AND TIME-UP INDICATORS; STANDARD SURFACE MOUNT CAN BE FLUSH MOUNTED USING ADAPTOR P/N Y92F-40, CAGE 61964 |
APNP | Duty Type | CONTINUOUS |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.