Buy Mil Spares is your sourcing solution for top-quality military and defense parts, aerospace parts, and other similar products that are necessary for operational fulfillment. You have reached the RFQ page for part number 7567513-031, a Reactor Transformer item that is listed with the NSN 5950-01-248-5938 for an ease of identification. Manufactured by General Dynamics Land Systems Inc and readily available for procurement today, you are always welcome to request a quote on this NSN part to receive tailored pricing information and fulfillment options from our team. Simply offer us important information like your desired quantity, price, and fulfillment timeframe, and our team will supply you with a tailored quote on part number 7567513-031 in 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that customers quickly identify and procure exact items, we list everything with as much relevant information as possible. For example, while part number 7567513-031 is manufactured by General Dynamics Land Systems Inc, it is specifically done so under CAGE Code 13160, a unique identifier assigned to a specific facility by the DLA that supplies to various government or defense agencies. Furthermore, using the first digits of the NSN 5950-01-248-5938, one can also determine that this part falls under FSC 5950 Coils and Transformers. With this in mind, continue exploring our website today, and see how we can help you secure competitive pricing and rapid lead times on all desired NSN parts.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-248-5938 Item PartTypeName: REACTOR-TRANSFORMER | 5950 | 012485938 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
7567513-031 | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHY | TURN QUANTITY | 1 4TH COMPONENT SINGLE PRIMARY |
ABHY | TURN QUANTITY | 105 2ND COMPONENT SINGLE WINDING |
ABHY | TURN QUANTITY | 12 3RD COMPONENT 3RD SECONDARY |
ABHY | TURN QUANTITY | 25 3RD COMPONENT 4TH SECONDARY |
ABHY | TURN QUANTITY | 32 3RD COMPONENT SINGLE PRIMARY |
ABHY | TURN QUANTITY | 4 3RD COMPONENT 1ST SECONDARY |
ABHY | TURN QUANTITY | 48 3RD COMPONENT 2ND SECONDARY |
ABHY | TURN QUANTITY | 500 4TH COMPONENT SINGLE SECONDARY |
ABHY | TURN QUANTITY | 7 1ST COMPONENT SINGLE WINDING |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.800 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACYV | INDUCTANCE RATING | 10.00 MICROHENRIES NOMINAL 1ST COMPONENT SINGLE WINDING |
ACYV | INDUCTANCE RATING | 90.00 MICROHENRIES MINIMUM 2ND COMPONENT SINGLE WINDING AND 3.10 MILLIHENRIES MAXIMUM 2ND COMPONENT SINGLE WINDING |
ACZB | FREQUENCY RATING | 20.0 KILOHERTZ NOMINAL 2ND COMPONENT |
ACZB | FREQUENCY RATING | 20.0 KILOHERTZ NOMINAL 3RD COMPONENT |
ACZB | FREQUENCY RATING | 20.0 KILOHERTZ NOMINAL 4TH COMPONENT |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL 1ST COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE 3RD COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE 4TH COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO TERMINAL 3RD COMPONENT |
ADAQ | BODY LENGTH | 3.300 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.010 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 1.630 INCHES MAXIMUM |
AGAV | END ITEM IDENTIFICATION | C5B ACFT; WSD: AIRCRAFT,GALAXY C-5 |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
BKPL | RATING METHOD | ELECTRICAL 1ST COMPONENT SINGLE WINDING AND WINDING TURNS 1ST COMPONENT SINGLE WINDING |
BKPL | RATING METHOD | ELECTRICAL 2ND COMPONENT SINGLE WINDING AND WINDING TURNS 2ND COMPONENT SINGLE WINDING |
BKPL | RATING METHOD | ELECTRICAL 3RD COMPONENT 1ST SECONDARY AND WINDING TURNS 3RD COMPONENT 1ST SECONDARY |
BKPL | RATING METHOD | ELECTRICAL 3RD COMPONENT 2ND SECONDARY AND WINDING TURNS 3RD COMPONENT 2ND SECONDARY |
BKPL | RATING METHOD | ELECTRICAL 3RD COMPONENT 3RD SECONDARY AND WINDING TURNS 3RD COMPONENT 3RD SECONDARY |
BKPL | RATING METHOD | ELECTRICAL 3RD COMPONENT 4TH SECONDARY AND WINDING TURNS 3RD COMPONENT 4TH SECONDARY |
BKPL | RATING METHOD | ELECTRICAL 3RD COMPONENT SINGLE PRIMARY AND WINDING TURNS 3RD COMPONENT SINGLE PRIMARY |
BKPL | RATING METHOD | WINDING TURNS 4TH COMPONENT SINGLE PRIMARY |
BKPL | RATING METHOD | WINDING TURNS 4TH COMPONENT SINGLE SECONDARY |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 3RD COMPONENT AND 6 SECONDARY 3RD COMPONENT |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 4TH COMPONENT AND 1 SECONDARY 4TH COMPONENT |
CQPZ | WINDING CONDUCTOR SIZE | 0.00200 INCHES AMERICAN WIRE GAGE 1ST COMPONENT SINGLE WINDING |
CQPZ | WINDING CONDUCTOR SIZE | 0.00500 INCHES AMERICAN WIRE GAGE 4TH COMPONENT SINGLE SECONDARY |
CQPZ | WINDING CONDUCTOR SIZE | 0.01594 INCHES AMERICAN WIRE GAGE 3RD COMPONENT 1ST SECONDARY |
CQPZ | WINDING CONDUCTOR SIZE | 0.01594 INCHES AMERICAN WIRE GAGE 3RD COMPONENT 2ND SECONDARY |
CQPZ | WINDING CONDUCTOR SIZE | 0.01594 INCHES AMERICAN WIRE GAGE 3RD COMPONENT 3RD SECONDARY |
CQPZ | WINDING CONDUCTOR SIZE | 0.01594 INCHES AMERICAN WIRE GAGE 3RD COMPONENT 4TH SECONDARY |
CQPZ | WINDING CONDUCTOR SIZE | 0.02257 INCHES AMERICAN WIRE GAGE 2ND COMPONENT SINGLE WINDING |
CQPZ | WINDING CONDUCTOR SIZE | 0.02535 INCHES AMERICAN WIRE GAGE 3RD COMPONENT SINGLE PRIMARY |
CQPZ | WINDING CONDUCTOR SIZE | 0.02535 INCHES AMERICAN WIRE GAGE 4TH COMPONENT SINGLE PRIMARY |
CRBZ | WINDING OPERATING CURRENT | 29.0 AMPERES DC MAXIMUM 2ND COMPONENT SINGLE WINDING |
CRBZ | WINDING OPERATING CURRENT | 30.0 AMPERES DC NOMINAL 1ST COMPONENT SINGLE WINDING |
CRGS | DC RESISTANCE RATING IN OHMS | 0.046 3RD COMPONENT SINGLE PRIMARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.120 3RD COMPONENT 3RD SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.132 3RD COMPONENT 1ST SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.240 3RD COMPONENT 4TH SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.760 3RD COMPONENT 2ND SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 14.000 4TH COMPONENT SINGLE SECONDARY |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
CWJS | WINDING OPERATING VOLTAGE | 0.10 AC VOLTS NOMINAL 1ST COMPONENT SINGLE WINDING |
CWJS | WINDING OPERATING VOLTAGE | 15.60 AC VOLTS NOMINAL 3RD COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 2.00 AC VOLTS NOMINAL 2ND COMPONENT SINGLE WINDING |
CWJS | WINDING OPERATING VOLTAGE | 2.50 AC VOLTS NOMINAL 3RD COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 20.00 AC VOLTS NOMINAL 3RD COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 30.00 AC VOLTS NOMINAL 3RD COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 7.48 AC VOLTS NOMINAL 3RD COMPONENT 3RD SECONDARY |
FEAT | SPECIAL FEATURES | WEAPON SYSTEM ESSENTIAL |
TTQY | TERMINAL TYPE AND QUANTITY | 28 TURRET |