Buy Mil Spares is your sourcing solution for top-quality military and defense parts, aerospace parts, and other similar products that are necessary for operational fulfillment. You have reached the RFQ page for part number HY292-3964-3, a Transformer Power item that is listed with the NSN 5950-00-318-6297 for an ease of identification. Manufactured by Dsk Engineering And Technology Inc and readily available for procurement today, you are always welcome to request a quote on this NSN part to receive tailored pricing information and fulfillment options from our team. Simply offer us important information like your desired quantity, price, and fulfillment timeframe, and our team will supply you with a tailored quote on part number HY292-3964-3 in 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that customers quickly identify and procure exact items, we list everything with as much relevant information as possible. For example, while part number HY292-3964-3 is manufactured by Dsk Engineering And Technology Inc, it is specifically done so under CAGE Code 02KE8, a unique identifier assigned to a specific facility by the DLA that supplies to various government or defense agencies. Furthermore, using the first digits of the NSN 5950-00-318-6297, one can also determine that this part falls under FSC 5950 Coils and Transformers. With this in mind, continue exploring our website today, and see how we can help you secure competitive pricing and rapid lead times on all desired NSN parts.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-318-6297 Item Description: Transformer Power | 5950 | 003186297 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Hy292-3964-3 | 5 | 1 | C | G |
MRC | Criteria | Characteristic |
---|---|---|
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.250 INCHES NOMINAL SINGLE MOUNTIN" |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
ABTB | MOUNTING HOLE DIAMETER | 0.281 INCHES NOMINAL SINGLE GROUP0.281 INCHES NOMINAL SINGLE GROUP" |
ACZB | FREQUENCY RATING | 57.0 HERTZ MINIMUM SINGLE COMPONENT AND 57.0 HERTZ MINIMUM SINGLE COMPONENT AND 57.0 HERTZ MAXIMUM SINGLE COMPONENT57.0 HERTZ MAXIMUM SINGLE COMPONENT" |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO SIX PHASE SINGLE COMPONENTTHREE PHASE TO SIX PHASE SINGLE COMPONENT" |
ADAQ | BODY LENGTH | 11.500 INCHES NOMINAL11.500 INCHES NOMINAL" |
ADAT | BODY WIDTH | 3.500 INCHES NOMINAL3.500 INCHES NOMINAL" |
ADAU | BODY HEIGHT | 8.500 INCHES NOMINAL8.500 INCHES NOMINAL" |
AKNA | INCLOSURE TYPE | OPENOPEN" |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP" |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUPTHREADED HOLE SINGLE GROUP" |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT1 SECONDARY SINGLE COMPONENT" |
CMLP | THREAD QUANTITY PER INCH | 20 SINGLE GROUP20 SINGLE GROUP" |
CQJX | NOMINAL THREAD SIZE | 0.250 INCHES SINGLE GROUP0.250 INCHES SINGLE GROUP" |
CRBZ | WINDING OPERATING CURRENT | 146.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY" |
CRMJ | WINDING POWER RATING | 2.34 KILOVOLT-AMPERES SINGLE COMPONENT SINGLE SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 16.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY208.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY" |
CWJS | WINDING OPERATING VOLTAGE | 208.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY" |
TEST | TEST DATA DOCUMENT | 81349-MIL-T-27 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING" |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP" |
TTQY | TERMINAL TYPE AND QUANTITY | 12 THREADED HOLE" |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.250 INCHES NOMINAL SINGLE MOUNTIN" |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
ABTB | MOUNTING HOLE DIAMETER | 0.281 INCHES NOMINAL SINGLE GROUP0.281 INCHES NOMINAL SINGLE GROUP" |
ACZB | FREQUENCY RATING | 57.0 HERTZ MINIMUM SINGLE COMPONENT AND 57.0 HERTZ MINIMUM SINGLE COMPONENT AND 57.0 HERTZ MAXIMUM SINGLE COMPONENT57.0 HERTZ MAXIMUM SINGLE COMPONENT" |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO SIX PHASE SINGLE COMPONENTTHREE PHASE TO SIX PHASE SINGLE COMPONENT" |
ADAQ | BODY LENGTH | 11.500 INCHES NOMINAL11.500 INCHES NOMINAL" |
ADAT | BODY WIDTH | 3.500 INCHES NOMINAL3.500 INCHES NOMINAL" |
ADAU | BODY HEIGHT | 8.500 INCHES NOMINAL8.500 INCHES NOMINAL" |
AKNA | INCLOSURE TYPE | OPENOPEN" |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP" |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUPTHREADED HOLE SINGLE GROUP" |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT1 SECONDARY SINGLE COMPONENT" |
CMLP | THREAD QUANTITY PER INCH | 20 SINGLE GROUP20 SINGLE GROUP" |
CQJX | NOMINAL THREAD SIZE | 0.250 INCHES SINGLE GROUP0.250 INCHES SINGLE GROUP" |
CRBZ | WINDING OPERATING CURRENT | 146.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY" |
CRMJ | WINDING POWER RATING | 2.34 KILOVOLT-AMPERES SINGLE COMPONENT SINGLE SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 16.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY208.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY" |
CWJS | WINDING OPERATING VOLTAGE | 208.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY" |
TEST | TEST DATA DOCUMENT | 81349-MIL-T-27 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING" |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP" |
TTQY | TERMINAL TYPE AND QUANTITY | 12 THREADED HOLE" |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.