For all the NSN 5950-00-549-1969 parts you are seeking, turn to our vast collection of offerings here on Buy Mil Spares. On this page, part numbers like 130-029-1, P3524, and others with the NSN 5950-00-549-1969 are featured alongside applicable listing information for your ease of perusal. If any specific item grabs your attention within our NSN 5950-00-549-1969 inventory, you can use the “RFQ” button to its right to access one of our online quote request forms. Once we have an opportunity to receive and assess the details you provided, you can anticipate a tailored response in 15 minutes or less.
To uphold the caliber of our stock, our industry experts carefully assess every supplier, manufacturer, and vendor we source from as needed, while countless components are evaluated by our quality-assurance team or subjected to third-party testing. In addition, we are aware that our customers often encounter rigid schedules and unexpected delivery deadlines, which is why we provide expedited shipping services for various items. Bearing this in mind, get in touch with one of our specialists today to see how we can help you secure all the NSN 5950-00-549-1969 supplies you require.
Item Name | Transformer Power |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5950 Coils and Transformers |
National Item Identification Number (NIIN) | 00-549-1969 (005491969) |
NCB Code | USA (00) |
Manufacturer | Bell Helicopter Textron Inc, Geotronic Labs Inc |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 5.031 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP5.031 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 4.571 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP4.571 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTB | MOUNTING HOLE DIAMETER | 0.202 INCHES MINIMUM SINGLE GROUP AND 0.202 INCHES MINIMUM SINGLE GROUP AND 0.208 INCHES MAXIMUM SINGLE GROUP0.208 INCHES MAXIMUM SINGLE GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 6.000 INCHES MAXIMUM6.000 INCHES MAXIMUM |
ADAT | BODY WIDTH | 3.938 INCHES MAXIMUM3.938 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 3.375 INCHES MAXIMUM3.375 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | FULLY INCLOSEDFULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUPUNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 2 PRIMARY SINGLE COMPONENT AND 5 SECONDARY SINGLE COMPONENT5 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 1.1 AMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 20.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 200.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 660.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 0.1 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY2.0 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
CRMJ | WINDING POWER RATING | 126.5 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 17.16 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY126.5 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 2.0 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY17.16 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 10.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY26.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY115.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 26.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY99.60 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 5.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY10.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 99.60 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY115.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
FEAT | SPECIAL FEATURES | 2 PRIMARY WINDINGS; 5 SECONDARY WINDINGS |
TTQY | TERMINAL TYPE AND QUANTITY | 1 CONNECTOR,RECEPTACLE |
Relevant Components for NSN - 5950-00-549-1969, 5950005491969 | ||||
5930-01-462-6780 (5930014626780) | 5945-00-606-0898 (5945006060898) | 5905-01-382-6125 (5905013826125) | 5950-00-236-0255 (5950002360255) | |
5905-00-501-9810 (5905005019810) | 5935-01-209-4889 (5935012094889) | 5962-01-433-9033 (5962014339033) | 5905-01-164-9998 (5905011649998) | |
5935-00-335-8347 (5935003358347) | 5905-01-298-3416 (5905012983416) | 5962-01-143-8927 (5962011438927) | 5940-01-290-4707 (5940012904707) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.