For all the NSN 5950-00-300-1957 parts you are seeking, turn to our vast collection of offerings here on Buy Mil Spares. On this page, part numbers like 20A2653-1, WE1949AM, and others with the NSN 5950-00-300-1957 are featured alongside applicable listing information for your ease of perusal. If any specific item grabs your attention within our NSN 5950-00-300-1957 inventory, you can use the “RFQ” button to its right to access one of our online quote request forms. Once we have an opportunity to receive and assess the details you provided, you can anticipate a tailored response in 15 minutes or less.
To uphold the caliber of our stock, our industry experts carefully assess every supplier, manufacturer, and vendor we source from as needed, while countless components are evaluated by our quality-assurance team or subjected to third-party testing. In addition, we are aware that our customers often encounter rigid schedules and unexpected delivery deadlines, which is why we provide expedited shipping services for various items. Bearing this in mind, get in touch with one of our specialists today to see how we can help you secure all the NSN 5950-00-300-1957 supplies you require.
Item Name | Transformer Power |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5950 Coils and Transformers |
National Item Identification Number (NIIN) | 00-300-1957 (003001957) |
NCB Code | USA (00) |
Manufacturer | Arrow Fasteners Inc, Koehlke Components Inc, Magnetika Inc, Wems Electronics |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.438 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.438 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABMK | OVERALL WIDTH | 2.750 INCHES MAXIMUM2.750 INCHES MAXIMUM |
ABTB | MOUNTING HOLE DIAMETER | 0.148 INCHES MINIMUM SINGLE GROUP AND 0.148 INCHES MINIMUM SINGLE GROUP AND 0.165 INCHES MAXIMUM SINGLE GROUP0.165 INCHES MAXIMUM SINGLE GROUP |
ACZB | FREQUENCY RATING | 380.0 HERTZ MINIMUM SINGLE COMPONENT AND 380.0 HERTZ MINIMUM SINGLE COMPONENT AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT420.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT AND THREE PHASE TO THREE PHASE SINGLE COMPONENT AND THREE PHASE TO SINGLE PHASE SINGLE COMPONENTTHREE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-DELTA |
ACZX | WINDING SHIELDING METHOD | INTERNALLY SHIELDED SINGLE COMPONENTINTERNALLY SHIELDED SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.630 INCHES MAXIMUM3.630 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 1.480 INCHES MAXIMUM1.480 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSEDFULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUPUNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 5 SECONDARY SINGLE COMPONENT5 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 0.1 AMPERES DC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 1.0 AMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 1.0 AMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 2.2 AMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 16.50 AC VOLTS MINIMUM SINGLE COMPONENT 4TH SECONDARY AND 38.00 AC VOLTS MINIMUM SINGLE COMPONENT 3RD SECONDARY AND 19.50 AC VOLTS MAXIMUM SINGLE COMPONENT 4TH SECONDARY42.00 AC VOLTS MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 184.00 AC VOLTS MINIMUM SINGLE COMPONENT SINGLE PRIMARY AND 16.50 AC VOLTS MINIMUM SINGLE COMPONENT 4TH SECONDARY AND 216.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY19.50 AC VOLTS MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 21.50 AC VOLTS MINIMUM SINGLE COMPONENT 1ST SECONDARY AND 24.50 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 21.50 AC VOLTS MINIMUM SINGLE COMPONENT 2ND SECONDARY AND 21.50 AC VOLTS MINIMUM SINGLE COMPONENT 1ST SECONDARY AND 24.50 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY24.50 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 38.00 AC VOLTS MINIMUM SINGLE COMPONENT 3RD SECONDARY AND 21.50 AC VOLTS MINIMUM SINGLE COMPONENT 2ND SECONDARY AND 42.00 AC VOLTS MAXIMUM SINGLE COMPONENT 3RD SECONDARY24.50 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
FEAT | SPECIAL FEATURES | 1PRIMARY,5 SECONDARIES; ALL CURRENTS ARE STATED AS RECTIFIED; 5TH SECONDARY RATINGS ARE THE SAME AS 4TH SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 18 TURRET |
Relevant Components for NSN - 5950-00-300-1957, 5950003001957 | ||||
5998-01-229-5332 (5998012295332) | 5935-01-129-6240 (5935011296240) | 5962-01-375-7347 (5962013757347) | 5985-01-173-5895 (5985011735895) | |
5935-01-448-0945 (5935014480945) | 5970-01-506-5523 (5970015065523) | 5998-01-285-1191 (5998012851191) | 5905-01-159-3200 (5905011593200) | |
5961-01-235-2883 (5961012352883) | 5905-00-195-2436 (5905001952436) | 5998-01-444-6854 (5998014446854) | 5930-01-364-9796 (5930013649796) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.