Item Name | Relay Electromagnetic |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5945 Relays and Solenoids |
National Item Identification Number (NIIN) | 01-510-2489 (015102489) |
NCB Code | USA (01) |
Manufacturer | Jered Llc, Tyco Electronics Corporation |
Part Number | Manufacturer | Item Name | Cage Code | RFQ |
---|---|---|---|---|
176565 | jered llc | relay electromagnetic | 98523 | RFQ |
20739005 REV J FN 18 | jered llc | relay electromagnetic | 98523 | RFQ |
R10-E1P6-115V | tyco electronics corporation | relay electromagnetic | 77342 | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 1.375 INCHES MAXIMUM" |
ABKW | OVERALL HEIGHT | 1.187 INCHES MAXIMUM" |
ABMK | OVERALL WIDTH | 0.735 INCHES MAXIMUM" |
ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF" |
AKDX | WINDING QUANTITY | 1" |
APCN | COIL QUANTITY | 1" |
APNP | DUTY TYPE | CONTINUOUS" |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED STUD SINGLE MOUNTING FACILITY" |
CQYJ | MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY" |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 6 POLE, DOUBLE THROW, ONE POSITION MOMENTARY" |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING AND 115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING" |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 3.0 AMPERES DC RESISTIVE LOAD AND 3.0 AMPERES AC RESISTIVE LOAD" |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 120.0 AC AND 28.0 DC" |
TTQY | TERMINAL TYPE AND QUANTITY | 22 TAB, SOLDER LUG ALL FUNCTIONS" |
ABHP | OVERALL LENGTH | 1.375 INCHES MAXIMUM" |
ABKW | OVERALL HEIGHT | 1.187 INCHES MAXIMUM" |
ABMK | OVERALL WIDTH | 0.735 INCHES MAXIMUM" |
ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF" |
AKDX | WINDING QUANTITY | 1" |
APCN | COIL QUANTITY | 1" |
APNP | DUTY TYPE | CONTINUOUS" |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED STUD SINGLE MOUNTING FACILITY" |
CQYJ | MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY" |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 6 POLE, DOUBLE THROW, ONE POSITION MOMENTARY" |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING AND 115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING" |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 3.0 AMPERES DC RESISTIVE LOAD AND 3.0 AMPERES AC RESISTIVE LOAD" |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 120.0 AC AND 28.0 DC" |
TTQY | TERMINAL TYPE AND QUANTITY | 22 TAB, SOLDER LUG ALL FUNCTIONS" |
Relevant Components for NSN - 5945-01-510-2489, 5945015102489 | ||||
5998-00-296-4216 (5998002964216) | 5915-00-078-1818 (5915000781818) | 5935-01-009-1946 (5935010091946) | 5935-01-253-8244 (5935012538244) | |
5935-00-666-1819 (5935006661819) | 5950-00-075-0957 (5950000750957) | 5999-01-064-4357 (5999010644357) | 5961-01-065-8073 (5961010658073) | |
5935-00-941-8990 (5935009418990) | 5998-01-386-1255 (5998013861255) | 5950-00-149-5129 (5950001495129) | 5905-01-591-7266 (5905015917266) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote